Eurocode 5 (EN 1995-1-1)

Design Xlam Dolomiti CLT to Eurocode 5

SPEC Toolbox designs Xlam Dolomiti CLT to Eurocode 5 (EN 1995-1-1), using the characteristic values of ETA-12/0347. The integration covers 26 spruce C24 layups, 3 to 8 layers and 60 to 300 mm thick, for load-bearing walls, floors and roofs in service classes 1 and 2. Rolling shear is verified to EN 1995-1-1 clause 6.1.7 against the assessed cross-layer strength of 1.8 N/mm2. The same panel values are used for design to the Australian and New Zealand standards.

Start Designing for Free → Back to Xlam Dolomiti → ETA-12/0347 · Issue Date: 20th April 2017

The engineer's guide

Designing Xlam Dolomiti CLT to Eurocode 5

Xlam Dolomiti (X-LAM Dolomiti S.r.l., Castel Ivano, Trentino, with its plant at Castelnuovo Valsugana, Italy) produces cross-laminated timber panels. Part of the Paterno Group, it covers design and engineering through to installation. The panels are assessed under ETA-12/0347, issued by the Austrian Institute of Construction Engineering (OIB). SPEC Toolbox designs them to Eurocode 5, using the characteristic values of that assessment.

Product range

The integration covers 26 Xlam Dolomiti CLT build-ups, spruce C24 in every layer, bonded crosswise at 90 degrees with an adhesive to EN 15425, the one-component polyurethane standard named in the assessment. The supplier records glue-line integrity with the HBX adhesive.

  • Layups. Six 3-ply panels from CL3/60 to CL3/120, twelve 5-ply panels from CL5/100 to CL5/200, seven 7-ply panels from CL7/180 to CL7/280, and one 8-ply panel, CL8/300.
  • Dimensions. Element thickness 60 to 300 mm; board thickness 19 to 40 mm across the integrated build-ups; board width 56 to 300 mm at a width-to-thickness ratio of at least 4 to 1.
  • Formats. Panels up to 3.5 m wide and 13.5 m long in production.
  • Jointing. Boards finger-jointed lengthwise to EN 14080, with no butt joints; edge gluing available; joints within a layer to a maximum width of 3 mm.
  • Finish and sourcing. Industrial, industrial-visual and visual surface qualities; PEFC chain of custody, a published Environmental Product Declaration, shop drawings and 3D models.

Compatibility

In the EU and ANZ scope the panels support:

  • Load-bearing walls, floors and roofs.
  • Service classes 1 and 2.
  • Industrial, industrial-visual and visual surfaces, with CNC machining, angled cuts and edge gluing.

What's distinctive

  • Declared panel values. The assessment declares a board modulus of elasticity of 12 000 N/mm2, a rolling-shear strength of 1.8 N/mm2 and a rolling-shear modulus of 50 N/mm2 for the cross layers, and an in-plane shear strength of 3.3 N/mm2 on the net section.
  • Bending strength scales with the cover layer. Bending strength is declared as 26.4 N/mm2 divided by a system factor ksys = max{1.0; 1.1 – 0.025n}, with n the number of boards in the cover layer. The factor departs from 1.0 only for three or fewer cover boards, so narrow elements are designed at down to about 24.6 N/mm2.
  • A fine-grained layup ladder. Twenty-six build-ups cover 60 to 300 mm, with 140, 160 and 200 mm each carried in two arrangements, so the layer pattern can be matched to the span direction and not only the depth.
  • Panel size set against the transport route. Production reaches 3.5 m by 13.5 m, and the length limit is recorded separately for containers (12 m) and other transport (13.5 m), which constrains panel scheduling from the Italian plant.
  • Impact resistance from the thinnest wall build-up. The assessment takes soft-body impact resistance as satisfied for walls of at least three layers and at least 60 mm, which the smallest integrated panel, CL3/60, meets exactly.

In the platform

The panels are available across the SPEC Toolbox CLT modules, worked to Eurocode 5:

  • CLT floor, CLT wall, CLT shear wall, CLT diaphragm and CLT floor penetration.

and in the connection modules:

  • the screw connection module and the panel-to-panel connection details (spline, butt joint and half-lap);
  • CLT floor-to-glulam beam, CLT floor-to-floor and CLT wall-to-wall connections.

Panel behaviour is taken from the integrated database with the exact characteristic values of ETA-12/0347, and the same values are used for design to the Australian and New Zealand standards. Fire design, vibration and other verifications not covered by the current Eurocode 5 can be checked against the new Eurocode 5 and other relevant documentation.

Design codes

Design follows Eurocode 5 (EN 1995-1-1). The panels are assessed under ETA-12/0347, which supplies the characteristic values used in design: the board modulus of elasticity (12 000 N/mm2) and the rolling-shear strength (1.8 N/mm2) and modulus (50 N/mm2) of the cross layers. Characteristic values become design values with the Eurocode load-duration and service factor and the material partial factor, kmod and kdef taken as for glued laminated timber; the declared bending strength additionally carries the system-factor reduction above. The assessment is for service classes 1 and 2; airborne and impact sound insulation, sound absorption and resistance to fire are not assessed in it.

Frequently asked questions

Design With Xlam Dolomiti

How current is the Xlam Dolomiti CLT data in SPEC Toolbox?

It is written against ETA-12/0347 of 20 April 2017, which converted the 2012 European technical approval of the same number. Values are re-checked at the assessment’s next reissue before the integrated data changes.

Which Xlam Dolomiti CLT products are part of the integration?

Twenty-six build-ups, spruce C24 in every layer, named for layer count and thickness, running from CL3/60 up to CL8/300. Double-lamella panels are not part of the current integration.

What can the panels be used for?

Load-bearing walls, floors and roofs in service classes 1 and 2, with industrial through to visual surface qualities. Members directly exposed to the weather need effective protection in service, and the assessment does not cover wood preservatives or flame retardants.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →
FOR SUPPLIERSBecome a partner

Get your products in front of every engineer specifying on the platform — at the point of design.

Get Your Products Specified →