Designing Xlam Dolomiti CLT to Eurocode 5
Xlam Dolomiti (X-LAM Dolomiti S.r.l., Castel Ivano, Trentino, with its plant at Castelnuovo Valsugana, Italy) produces cross-laminated timber panels. Part of the Paterno Group, it covers design and engineering through to installation. The panels are assessed under ETA-12/0347, issued by the Austrian Institute of Construction Engineering (OIB). SPEC Toolbox designs them to Eurocode 5, using the characteristic values of that assessment.
The integration covers 26 Xlam Dolomiti CLT build-ups, spruce C24 in every layer, bonded crosswise at 90 degrees with an adhesive to EN 15425, the one-component polyurethane standard named in the assessment. The supplier records glue-line integrity with the HBX adhesive.
In the EU and ANZ scope the panels support:
The panels are available across the SPEC Toolbox CLT modules, worked to Eurocode 5:
and in the connection modules:
Panel behaviour is taken from the integrated database with the exact characteristic values of ETA-12/0347, and the same values are used for design to the Australian and New Zealand standards. Fire design, vibration and other verifications not covered by the current Eurocode 5 can be checked against the new Eurocode 5 and other relevant documentation.
Design follows Eurocode 5 (EN 1995-1-1). The panels are assessed under ETA-12/0347, which supplies the characteristic values used in design: the board modulus of elasticity (12 000 N/mm2) and the rolling-shear strength (1.8 N/mm2) and modulus (50 N/mm2) of the cross layers. Characteristic values become design values with the Eurocode load-duration and service factor and the material partial factor, kmod and kdef taken as for glued laminated timber; the declared bending strength additionally carries the system-factor reduction above. The assessment is for service classes 1 and 2; airborne and impact sound insulation, sound absorption and resistance to fire are not assessed in it.
It is written against ETA-12/0347 of 20 April 2017, which converted the 2012 European technical approval of the same number. Values are re-checked at the assessment’s next reissue before the integrated data changes.
Twenty-six build-ups, spruce C24 in every layer, named for layer count and thickness, running from CL3/60 up to CL8/300. Double-lamella panels are not part of the current integration.
Load-bearing walls, floors and roofs in service classes 1 and 2, with industrial through to visual surface qualities. Members directly exposed to the weather need effective protection in service, and the assessment does not cover wood preservatives or flame retardants.
Free, browser-based, no download. Design any certified connection into your real materials in seconds.
Start Designing For Free →Get your products in front of every engineer specifying on the platform — at the point of design.