Eurocode 5 (EN 1995-1-1)

Design KLH® – CLT to Eurocode 5

SPEC Toolbox designs KLH cross-laminated timber to Eurocode 5 (EN 1995-1-1) using the characteristic values of ETA-06/0138. The integration covers 45 spruce C24 layups in 3, 5, 7 and 8 layer build-ups, 60 to 320 mm thick, in panels up to 3.5 m wide and 16.5 m long, for load-bearing walls, floors and roofs in service classes 1 and 2. The same panel values are used for design to the Australian and New Zealand standards.

Start Designing for Free → Back to KLH → ETA-06/0138 · Issue Date: 18th January 2021

The engineer's guide

Designing KLH® – CLT to Eurocode 5

KLH Massivholz GmbH, founded in 1996, manufactures KLH cross-laminated timber at Teufenbach-Katsch and at Bad St. Leonhard in Austria. The panels are assessed under ETA-06/0138, issued by the Austrian Institute of Construction Engineering (OIB). SPEC Toolbox designs them to Eurocode 5, using the characteristic values of that assessment.

Product range

The integration covers 45 KLH cross-laminated timber layups, spruce graded to C24 in every layer, bonded crosswise with a one-component polyurethane adhesive to EN 15425 and finger-jointed to EN 14080.

  • 3, 5, 7 and 8 layer build-ups, element thickness 60 to 320 mm, assembled from 20, 30 and 40 mm layers.
  • Panels up to 3.5 m wide and 16.5 m long, which is also the maximum transport length.
  • Boards 44 to 298 mm wide, minimum board width to thickness ratio 4:1, with the lamella edges glued within each layer.
  • Non-visual, industrial-visual and domestic-visual surface qualities.
  • FSC and PEFC chain of custody, and a published Environmental Product Declaration.

Compatibility

At a glance, in the EU and ANZ scope the KLH panels support:

  • Load-bearing walls, floors and roofs.
  • Service classes 1 and 2.
  • Visual or non-visual surfaces, with CNC machining and angled cuts.

What's distinctive

  • Declared panel values. The assessment declares a mean modulus of elasticity of 12 000 N/mm2 for the boards, a rolling-shear strength of 1.2 N/mm2 and a rolling-shear modulus of 50 N/mm2 for the cross layers, and a shear flow of 90 N/mm per glue line for in-plane shear.
  • In-plane shear strength graded by layer thickness. The in-plane shear strength is declared as a function of lamella thickness, from 8.4 N/mm2 at 19 mm down to 3.9 N/mm2 at 45 mm, with a 25 percent increase for inner layers, so thin-lamella build-ups carry more in-plane shear.
  • Paired-layer build-ups to 320 mm. The 5ss, 7ss and 8ss layups place two adjacent 30 or 40 mm layers in the same direction, within the 90 mm limit the assessment sets for consecutive same-direction layers, and reach 300 and 320 mm on eight layers.
  • Two build-ups at the same thickness. Most thicknesses are carried in two families that split the section differently between the layers parallel to the panel length and the cross layers: a 100 mm three-layer panel is built up either 40/20/40 or 30/40/30.
  • A declared system strength factor. The assessment sets ksys between 0.90 and 1.10, by member width for loading perpendicular to the panel and by number of layers for loading in plane, so wide panels and multi-layer sections take a declared increase.

In the platform

The KLH panels are available across the SPEC Toolbox CLT modules, worked to Eurocode 5:

  • CLT floor, CLT wall, CLT shear wall, CLT diaphragm and CLT floor penetration.

and in the connection modules:

  • the screw connection module and the panel-to-panel connection details (spline, butt joint and half-lap);
  • CLT floor-to-glulam beam, CLT floor-to-floor and CLT wall-to-wall connections.

Panel behaviour is taken from the integrated database with the exact characteristic values of ETA-06/0138, and the same values are used for design to the Australian and New Zealand standards. Fire design, vibration and other verifications not covered by the current Eurocode 5 can be checked against the new Eurocode 5 and other relevant documentation.

Design codes

Design follows Eurocode 5 (EN 1995-1-1). The panels are assessed under ETA-06/0138, which supplies the characteristic values used in design, including the board modulus of elasticity of 12 000 N/mm2 and the rolling-shear strength and modulus of the cross layers. The assessment reduces the in-plane shear modulus to 250 N/mm2 for a simplified beam analysis, limits bending stresses in a simplified stress analysis to 90 percent of the design strength within the span and 70 percent close to supports and concentrated loads, and sets the crack factor to unity for shear perpendicular to the plane. The assessed service classes are 1 and 2. Structural fire design uses the charring rates declared in the assessment, 0.55 to 0.65 mm/min within a layer and 0.80 to 0.90 mm/min once a layer has fallen off, and the assessment also carries tested airborne and impact sound insulation for wall, floor and roof build-ups. Sound absorption is not assessed.

More from this partner

Other KLH Integrations

CLT (cross-laminated timber) design icon
CLT

KLH® – CLT

CSA O86 (CSA O86:24) Calculator →
CLT (cross-laminated timber) design icon
CLT

KLH® – CLT

the NDS (ANSI/AWC NDS) under the IBC / IRC Calculator →
In their words

Why KLH Massivholz builds on SPEC

“We have established a partnership with SPEC Toolbox to foster innovation, which aligns with our core values. We strongly believe in the advantages of making mass timber calculations more accessible by enhancing engineers’ capabilities. We aim to not only facilitate the process but also continually improve the precision and quality of calculation results.”

— Stefan Fritz, Senior Area Manager, KLH

Frequently asked questions

Design With KLH

How current is the KLH® – CLT data in SPEC Toolbox?

It is written against ETA-06/0138 of 18 January 2021, which replaced the 20 February 2017 issue. The integrated values are re-checked against the assessment when it is reissued.

Which KLH® – CLT products are part of the integration?

45 cross-laminated timber layups in spruce C24, carried under KLH’s own element designations: 3, 5, 7 and 8 layer build-ups from 60 to 320 mm, assembled from 20, 30 and 40 mm layers. Build-ups outside that range are not part of the integrated data.

What can the panels be used for?

Load-bearing walls, floors and roofs in service classes 1 and 2. The assessment covers static and quasi-static actions, and members directly exposed to the weather have to be given effective protection in service.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →