SPEC Toolbox designs Nordic Structures Nordic Lam glued laminated timber to the NDS (ANSI/AWC NDS) under the IBC and IRC, using the reference design values of ICC-ES ESR-4874, in ASD or LRFD. The integration covers the Nordic Lam beam layups (20F and 24F stress classes) and column combinations (ES11 and ES12) in Eastern spruce, in sections to 27 in. wide, 54 in. deep and 80 ft long. The grade values are taken from the integrated database.

Start Designing for Free → Back to Nordic Structures → ICC-ES ESR-4874 · Issue Date: September 2024

The engineer's guide

Designing Nordic Structures glulam to the NDS

Nordic Structures (Montreal, Quebec; manufactured in Chibougamau) produces Nordic Lam (also marketed as Nordic Lam+) glued laminated timber. In the US it is recognized under ICC-ES ESR-4874. SPEC Toolbox designs the beams and columns to the NDS, in allowable stress design or LRFD.

Product range

The integration covers Nordic Lam, glued laminated timber in Spruce-Pine-Fir (mainly Eastern spruce), grouped by role.

Beam layups

  • The 20F stress classes (20F-E8M1, 20F-ES/CPG) and the 24F stress classes (24F-E/ES1M1, 24F-ES/MSR, 24F-ES/NPG), plus the 1,350Fb-1.6E/ES1 layup, in balanced and unbalanced arrangements.

Column combinations

  • ES11 and ES12 (with NPG variants), for members stressed primarily in compression or axial loading.

Sections run to 27 in. wide, 54 in. deep and 80 ft long. Uses include beams, headers, rafters, purlins, columns, studs and decking.

Compatibility

At a glance, in the US scope the Nordic Lam supports:

  • Beams and columns.
  • Allowable stress design (ASD) or LRFD.
  • Dry service, with wet-use factors available for wet conditions.
  • Compliance with the Chicago, Los Angeles and California building codes.

What's distinctive

  • Bending and column layups. Beam stress classes from 20F to 24F (24F-ES to 2,400 psi bending and 1.9 x 10^6 psi modulus of elasticity) and column combinations ES11 and ES12, in balanced and unbalanced arrangements.
  • Large sections and long members. Sections reach 27 in. wide, 54 in. deep and 80 ft long, for long-span beams and heavy columns.
  • Designed in ASD or LRFD. The reference design values convert to LRFD strengths through the NDS Table 5.3.1 factors.
  • Fire resistance to two hours. Nordic Lam may be designed for fire exposure up to 2 hours per NDS Chapter 16, with an ASTM E84 Class B surface-burning rating.

In the platform

The Nordic Lam members are available across the SPEC Toolbox member-design modules, worked in ASD or LRFD to the NDS:

  • Timber beam and Timber column.

and in the connection modules:

  • the screw connection module and the CLT floor-to-glulam beam connection.

Member behaviour is taken from the integrated database with the reference design values of ESR-4874, using the specific gravity given in the report for fastener design.

Design codes

Design follows the ANSI/AWC NDS under the IBC and IRC. ICC-ES ESR-4874 publishes ASD reference design values for Nordic Lam beams and columns, manufactured to ANSI A190.1 and developed per ASTM D3737: bending, modulus of elasticity, shear, compression perpendicular and parallel to grain, and tension. These are adjusted per NDS Table 5.3.1 and the table footnotes, among them the volume factor, the flat-use factor and beam and column stability; LRFD strengths are obtained by multiplying by the NDS Table 5.3.1 factors. The species is Eastern spruce, with a specific gravity of 0.41 (0.46 for the NPG layups) for connection design. Tabulated values are for dry service, with wet-use factors provided for wet conditions; fire resistance is determined by calculation per NDS Chapter 16, for up to 2 hours. The members also carry Chicago, Los Angeles and California building-code supplements.

More from this partner

Other Nordic Structures Integrations

CLT (cross-laminated timber) design icon
CLT

CLT

CSA O86 (CSA O86:19) Calculator →
CLT (cross-laminated timber) design icon
CLT

CLT

the NDS (ANSI/AWC NDS) under the IBC / IRC Calculator →
Glulam beam and column design icon
Glulam

Glulam

CSA O86 (CSA O86:19) Calculator →
Frequently asked questions

FAQs

How current is the Nordic Structures glulam data in SPEC Toolbox?

It is written against ICC-ES ESR-4874, reissued September 2024 (subject to renewal September 2026), including its Chicago, Los Angeles and California supplements. Values are re-checked against the report at its next reissue before the integrated data changes.

Which Nordic Structures glulam products are part of the integration?

Nordic Lam (also marketed as Nordic Lam+): the beam layups (20F and 24F stress classes, including 24F-ES/NPG) and the column combinations ES11 and ES12, in Eastern spruce, in sections to 27 in. wide, 54 in. deep and 80 ft long.

What can the glulam be used for?

Beams, headers, rafters, purlins, columns, studs and decking, in ASD or LRFD, in dry service, with wet-use factors available for wet conditions.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →
FOR SUPPLIERSBecome a partner

Get your products in front of every engineer specifying on the platform — at the point of design.

Get Your Products Specified →
Close Menu