Eurocode 5 (EN 1995-1-1)

Design Södra CLT to Eurocode 5

SPEC Toolbox designs Södra CLT to Eurocode 5 (EN 1995-1-1) using the characteristic values of ETA-24/1212. The integration covers spruce C24 panels from the Väröbacka plant in 3, 5 and 7 layers, 60 to 280 mm thick, up to 3.5 m wide and 16 m long, for load-bearing walls, floors and roofs in service classes 1 and 2. Connections are designed to EN 1995-1-1 Section 8 as amended by Annex 4 of the assessment. The panel values come from the integrated database.

Start Designing for Free → Back to Södra → ETA-24/1212 · Issue Date: 15th January 2025

The engineer's guide

Designing Södra CLT to Eurocode 5

Södra (Södra Skogsägarna ekonomisk förening, Växjö) is a Swedish forest owners’ association that manufactures cross laminated timber at Väröbacka. SÖDRA CLT is assessed under ETA-24/1212, issued by ETA-Danmark A/S. SPEC Toolbox designs the panels to Eurocode 5 using the characteristic values of that assessment.

Product range

SÖDRA CLT is spruce with C24 boards in every layer, bonded crosswise with a one-component polyurethane adhesive of type I to EN 15425. Boards are finger-jointed lengthwise to EN 14080; butt joints are not permitted.

  • Sixty-two integrated layups. L-panels place the outer layer parallel to the production direction, in 3, 5 and 7 layers from 60 to 280 mm; C-panels place it perpendicular, in 3 and 5 layers from 60 to 200 mm.
  • Lamella thicknesses of 20, 30 and 40 mm; board width 80 to 250 mm. Cross layers are not edge glued and hold a board width-to-thickness ratio of at least 4:1.
  • Panels up to 3.5 m wide and 16 m long, with a thickness tolerance of the greater of 2 mm and 2 per cent of thickness, and width and length tolerances of 3 mm.
  • Non-visual and visual surfaces, with CNC machining and angled cuts.

Compatibility

At a glance, in the EU scope the Södra panels support:

  • Load-bearing walls, floors and roofs.
  • Service classes 1 and 2.
  • Visual or non-visual surfaces, with CNC machining and angled cuts.

What's distinctive

  • Rolling shear that varies with layer thickness. The assessment gives the rolling shear strength of the cross layers as a function of layer thickness, capped at 1.4 N/mm2: the integrated 20, 30 and 40 mm cross layers carry 1.4, 1.28 and 1.16 N/mm2, against a rolling shear modulus of 50 N/mm2.
  • A three-part in-plane shear check. For in-plane actions the assessment sets the shear strength as the lowest of a gross-section value of 4.0 N/mm2, a net-section value of 8.0 N/mm2 across the joints between non-edge-glued boards, and a torsional value of 2.5 N/mm2 in the crossing areas. Eurocode 5 has no in-plane shear verification for CLT.
  • Layups with paired parallel layers. Sixteen of the integrated layups run two adjacent layers in the same grain direction, which the assessment allows in elements of five layers or more up to a combined 90 mm. The 200 mm five-layer L-panel pairs two 40 mm longitudinal layers on each face.
  • Formaldehyde-free bond and a fossil-free plant. The polyurethane glue line is formaldehyde-free, and Södra reports that Väröbacka runs on fossil-free energy generated on site. The panels carry FSC and PEFC chain of custody, an Environmental Product Declaration, plus shop drawings and 3D models.

In the platform

The Södra panels are available across the SPEC Toolbox CLT modules, worked to Eurocode 5:

  • CLT floor, CLT wall, CLT shear wall, CLT diaphragm and CLT floor penetration.

and in the connection modules:

  • the screw connection module and the panel-to-panel connection details (spline, butt joint and half-lap);
  • CLT floor-to-glulam beam, CLT floor-to-floor and CLT wall-to-wall connections.

Panel behaviour is taken from the integrated database with the exact characteristic values of ETA-24/1212, and the same values are used for design to the Australian and New Zealand standards. Fire design, vibration and other verifications not covered by the current Eurocode 5 can be checked against the new Eurocode 5 and other relevant documentation.

Design codes

Design follows Eurocode 5 (EN 1995-1-1). The panels are assessed under ETA-24/1212, which supplies the characteristic values used in design: a board modulus of elasticity of 12 000 N/mm2 for C24, a board bending strength of 24 N/mm2 before the system strength factor, tensile and compressive strengths parallel to grain of 19 and 24 N/mm2, a characteristic density of 385 kg/m3, and the rolling shear strength and modulus of the cross layers. The assessment covers service classes 1 and 2 and static and quasi-static actions, including seismic actions to EN 1998-1; tension perpendicular to the element should be avoided. Connections follow Section 8 of Eurocode 5 as amended by Annex 4 of the assessment. Sound insulation is not assessed in the ETA; for fire it declares reaction to fire Euroclass D-s2,d0 and charring rates of 0.65 mm/min and 0.7 mm/min, but no resistance-to-fire rating.

Frequently asked questions

Design With Södra

How current is the Södra CLT data in SPEC Toolbox?

It is written against ETA-24/1212, issued 15 January 2025 by ETA-Danmark A/S. Values are re-checked at the assessment’s next reissue before the integrated data changes.

Which Södra CLT products are part of the integration?

Sixty-two layups of SÖDRA CLT, spruce with C24 boards throughout, built from 20, 30 and 40 mm lamellae: L-panels in 3, 5 and 7 layers from 60 to 280 mm, and C-panels in 3 and 5 layers from 60 to 200 mm.

What can the panels be used for?

Load-bearing walls, floors and roofs in service classes 1 and 2, up to 3.5 m wide and 16 m long. Elements exposed to the weather need effective protection, and wood preservatives and flame retardants are outside the assessment.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →
FOR SUPPLIERSBecome a partner

Get your products in front of every engineer specifying on the platform — at the point of design.

Get Your Products Specified →
Close Menu