Last Updated: January 22, 2023
Design Software for Structural Engineers

Design Dowel & Bolt Connections to Eurocode 5

Design timber dowel and bolt connections in Europe to Eurocode 5, with real timber and fastener properties built into every check rather than generic assumptions. Model single, double or multi-plate shear configurations, combined loading, and brittle block or plug shear, all verified automatically. See the connection modelled visually before committing to a detail. Try the calculator to specify your next connection with confidence.

Start Designing for Free → See Integrated Suppliers →
  • Standard: EN 1995-1-1:2004 (Eurocode 5), draft prEN 1995:2025
Dowel & Bolt

About Dowel & Bolt · Eurocode 5

The "Hardest" Part of Timber Design, Solved

Connection design is often the bottleneck in mass timber engineering. The complexity of the Johansen Yield Equations, combined with strict spacing rules and brittle failure modes, makes manual calculation slow and error-prone.

The SPEC Toolbox Dowel & Bolt Module is a complete transformation of how engineers handle connection complexity. It moves beyond simple “Shear Capacity” to a true Combined Actions Analysis. Whether you are designing a double-shear truss node, a moment-resisting portal frame knee, or a heavy beam-to-column bracket, this tool provides instant verification to EN 1995-1-1 and prepares you for the future with FprEN 1995:2025 checks.

The engineer's guide

Dowel & Bolt · Eurocode 5

What This Calculator Does

This tool utilizes a dynamic visual engine to optimize dowels, bolts, and steel plates in real-time. It performs a rigorous analysis of:

  • Lateral Load Capacity (Fv,Rd): Solves all Johansen Yield modes (Modes a–k) for single, double, and multiple shear planes.
  • Combined Actions: The new standard for connection design — analyzes connections under simultaneous Shear, Axial Tension, and Bending Moments, checking the interaction ratios for every fastener in the group.
  • Complex Configurations: Supports Timber-to-Timber, Steel-to-Timber (internal/external plates), and complex multi-plate setups (up to 4 shear planes).
  • Brittle Failure: Automates the critical “Block Shear” and “Plug Shear” checks (Annex A) which often govern capacity in high-load connections.
  • Geometry & Spacing: automatically verifies minimum edge (a4,c) and end (a3,t) distances to prevent splitting.

Overview of Dowel-Type Timber Connections

For the European region, the calculator supports: EN 1995-1-1:2004 (Eurocode 5), prEN 1995:2025 (Next-generation Eurocode revision). These standards define the design procedures for dowel-type fasteners using Johansen yield theory, spacing requirements, and timber failure checks. Supports bolts and steel dowels installed in glulam or solid timber members, allowing flexible configuration of plate positions, fastener layouts, and loading conditions.

Applied Forces and Connection Configuration

Loads: Axial Tension Force (Fx) — force parallel to connection axis producing tension in timber and fastener group; Shear Force (Fz) — perpendicular to fastener axis, transferred through bearing; Bending Moment (My) — introduces additional force redistribution within the fastener group. Engineers also define connection configuration — primary structural element or part of a larger load transfer system.

Yield Model Analysis for Dowel-Type Fasteners

Evaluates connections using Johansen Yield Theory, the foundation for modern timber connection design in Eurocode 5. Considers: timber embedment strength, fastener bending resistance, steel plate stiffness, load redistribution within the fastener group. Evaluates: timber embedding failure, fastener yielding, combined timber-fastener plastic mechanisms. Applies material safety factors and modification factors defined by the selected design standard.

Timber Member Configuration

Define: timber member thickness, timber material grade, steel plate placement within the timber section, plate arrangement (uniform or non-uniform). These determine load transfer mechanism and influence fastener spacing requirements, splitting resistance, overall joint behavior.

Steel Plate Properties

Steel plate grade, plate thickness, plate depth, edge distances, end distances. Material properties: yield strength and ultimate strength. System verifies plate against: plate bending, bearing capacity, shear capacity, block tearing resistance, tension capacity.

Fastener Type and Mechanical Properties

Supports Bolts, Steel dowels. Define: fastener diameter, fastener grade, number of fasteners per row, number of rows, fastener distribution pattern, washer diameter, installation angle.

Spacing and Edge Distance Requirements

Define: spacing along the grain (a1), spacing across the grain (a2), loaded edge distance (at), unloaded edge distance (ae), end distances. Manual definition or calculator-applied minimum spacing requirements per selected standard.

Automated Connection Capacity Checks

Geometric Verification: spacing/edge distances/layout satisfy design code provisions.

Timber Member and Fastener Checks: fastener yielding resistance, timber splitting resistance, block or plug shear resistance, net tension resistance of the timber member.

Steel Plate Verification: tension capacity, bearing resistance, bending capacity, shear capacity, block tearing resistance.

Results presented in a clear output summary dashboard.

Frequently asked questions

Dowel & Bolt · Eurocode 5

What is the difference between a Dowel and a Bolt?
In Eurocode 5, Bolts have nuts/washers and rely on the "Rope Effect" for extra strength. Dowels are tight-fitting smooth pins with no rope effect. Our calculator supports both, plus fitted bolts.
Does it check Block Shear?
Yes. Block Shear (tearing out a "chunk" of wood) is often the governing failure mode for groups of bolts loaded parallel to grain. We apply the rigorous checks from Annex A of Eurocode 5.
Is FprEN 1995-1-1:2025 supported?
Yes. We have integrated the latest draft provisions from the "Second Generation Eurocode," allowing you to future-proof your designs or compare current EC5 results against the upcoming standard.

What’s News

Dive into our newest releases, articles, and tutorials designed to help you succeed.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →
FOR SUPPLIERSBecome a partner

Get your products in front of every engineer specifying on the platform — at the point of design.

Get Your Products Specified →
Close Menu