Designing Nordic Structures glulam to CSA O86
Nordic Structures (Chibougamau, Quebec) produces Nordic Lam glued laminated timber. In Canada it is recognized under APA Product Report PR-L294(C). SPEC Toolbox designs the beams and columns to CSA O86, in limit states design.
The integration covers Nordic Lam, glued laminated timber in Spruce-Pine-Fir (mainly Eastern spruce), manufactured to CSA O122, grouped by role.
Beam stress grades
Column combinations
Sections run to 686 mm wide, 1372 mm deep and 24.4 m long. Uses include beams, headers, rafters, purlins, columns, studs and decking.
At a glance, in the Canadian scope the Nordic Lam supports:
The Nordic Lam members are available across the SPEC Toolbox member-design modules, worked to CSA O86:
and in the connection modules:
Member behaviour is taken from the integrated database with the LSD specified strengths of PR-L294(C), using the relative density given in the report for fastener design.
Design follows CSA O86 (CSA O86:19, limit states design) under the National Building Code of Canada. APA Product Report PR-L294(C) publishes LSD specified strengths in MPa for Nordic Lam beams and columns, manufactured to CSA O122 and developed per ASTM D3737: bending, modulus of elasticity, longitudinal shear, compression perpendicular and parallel to grain, and tension. Factored resistances are obtained with the CSA O86 modification factors, among them the load-duration, service-condition, size and bearing factors. The species is Eastern spruce with a relative density of 0.42 (0.47 for the NPG layups) for connection design. Tabulated values are for standard-term duration and dry service, with wet-use factors provided for wet conditions; fire design follows Annex B of CSA O86, for up to 2 hours.
It is written against APA Product Report PR-L294(C), revised 21 December 2025. The report is subject to APA re-examination within one year, so it is re-checked before the integrated data changes.
Nordic Lam: the beam stress grades 20F (20F-ES/CPG, 20F-E8M1) and 24F (24F-E/ES1M1, 24F-ES/MSR, 24F-ES/NPG) and the column combinations ES11 and ES12, in Eastern spruce, in sections to 686 mm wide, 1372 mm deep and 24.4 m long.
Beams, headers, rafters, purlins, columns, studs and decking, in limit states design (LSD), in dry service, with wet-use factors available for wet conditions.
Free, browser-based, no download. Design any certified connection into your real materials in seconds.
Start Designing For Free →Get your products in front of every engineer specifying on the platform — at the point of design.