CSA O86 (CSA O86:19)

Design Nordic Structures Glulam to CSA O86

SPEC Toolbox designs Nordic Structures Nordic Lam glued laminated timber to CSA O86 under the National Building Code of Canada, using the LSD specified strengths of APA Product Report PR-L294(C). The integration covers the Nordic Lam beam stress grades (20F and 24F) and column combinations (ES11 and ES12) in Eastern spruce, in sections to 686 mm wide, 1372 mm deep and 24.4 m long. The grade values are taken from the integrated database.

Start Designing for Free → Back to Nordic Structures → APA PR-L294(C) · Issue Date: 21st December 2025

The engineer's guide

Designing Nordic Structures glulam to CSA O86

Nordic Structures (Chibougamau, Quebec) produces Nordic Lam glued laminated timber. In Canada it is recognized under APA Product Report PR-L294(C). SPEC Toolbox designs the beams and columns to CSA O86, in limit states design.

Product range

The integration covers Nordic Lam, glued laminated timber in Spruce-Pine-Fir (mainly Eastern spruce), manufactured to CSA O122, grouped by role.

Beam stress grades

  • 20F (20F-ES/CPG, 20F-E8M1) and 24F (24F-E/ES1M1, 24F-ES/MSR, 24F-ES/NPG), in balanced and unbalanced arrangements.

Column combinations

  • ES11 and ES12 (with NPG variants), for members stressed primarily in compression or axial loading.

Sections run to 686 mm wide, 1372 mm deep and 24.4 m long. Uses include beams, headers, rafters, purlins, columns, studs and decking.

Compatibility

At a glance, in the Canadian scope the Nordic Lam supports:

  • Beams and columns.
  • Limit states design (LSD).
  • Dry service, with wet-use factors available for wet conditions.

What's distinctive

  • Beam and column layups. Beam stress grades from 20F to 24F (24F-1.9E carries a specified bending strength of 30.7 MPa and a modulus of elasticity of 13 100 MPa) and column combinations ES11 and ES12, in balanced and unbalanced arrangements.
  • Large sections and long members. Sections reach 686 mm wide, 1372 mm deep and 24.4 m long, for long-span beams and heavy columns.
  • Eastern spruce glulam to CSA O122. Manufactured from Spruce-Pine-Fir, mainly Black spruce, with a relative density of 0.42 (0.47 for the NPG layups) for connection design.
  • Fire resistance to two hours. Nordic Lam may be designed for fire exposure up to 2 hours per Annex B of CSA O86, with a CAN/ULC S102 flame-spread rating of 0 to 25 at depths of 86 mm and above.

In the platform

The Nordic Lam members are available across the SPEC Toolbox member-design modules, worked to CSA O86:

  • Timber beam and Timber column.

and in the connection modules:

  • the screw connection module and the CLT floor-to-glulam beam connection.

Member behaviour is taken from the integrated database with the LSD specified strengths of PR-L294(C), using the relative density given in the report for fastener design.

Design codes

Design follows CSA O86 (CSA O86:19, limit states design) under the National Building Code of Canada. APA Product Report PR-L294(C) publishes LSD specified strengths in MPa for Nordic Lam beams and columns, manufactured to CSA O122 and developed per ASTM D3737: bending, modulus of elasticity, longitudinal shear, compression perpendicular and parallel to grain, and tension. Factored resistances are obtained with the CSA O86 modification factors, among them the load-duration, service-condition, size and bearing factors. The species is Eastern spruce with a relative density of 0.42 (0.47 for the NPG layups) for connection design. Tabulated values are for standard-term duration and dry service, with wet-use factors provided for wet conditions; fire design follows Annex B of CSA O86, for up to 2 hours.

More from this partner

Other Nordic Structures Integrations

CLT (cross-laminated timber) design icon
CLT

CLT

CSA O86 (CSA O86:19) Calculator →
CLT (cross-laminated timber) design icon
CLT

CLT

the NDS (ANSI/AWC NDS) under the IBC / IRC Calculator →
Glulam beam and column design icon
Glulam

Glulam

the NDS (ANSI/AWC NDS) under the IBC / IRC Calculator →
Frequently asked questions

FAQs

How current is the Nordic Structures glulam data in SPEC Toolbox?

It is written against APA Product Report PR-L294(C), revised 21 December 2025. The report is subject to APA re-examination within one year, so it is re-checked before the integrated data changes.

Which Nordic Structures glulam products are part of the integration?

Nordic Lam: the beam stress grades 20F (20F-ES/CPG, 20F-E8M1) and 24F (24F-E/ES1M1, 24F-ES/MSR, 24F-ES/NPG) and the column combinations ES11 and ES12, in Eastern spruce, in sections to 686 mm wide, 1372 mm deep and 24.4 m long.

What can the glulam be used for?

Beams, headers, rafters, purlins, columns, studs and decking, in limit states design (LSD), in dry service, with wet-use factors available for wet conditions.

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →
FOR SUPPLIERSBecome a partner

Get your products in front of every engineer specifying on the platform — at the point of design.

Get Your Products Specified →
Close Menu