the NDS (ANSI/AWC NDS) under the IBC / IRC

Design Nordic Structures CLT to the NDS

SPEC Toolbox designs Nordic Structures Nordic X-Lam cross-laminated timber to the NDS (ANSI/AWC NDS) under the IBC and IRC, using the reference design values of ICC-ES ESR-4875 (rated to ANSI/APA PRG-320), in ASD or LRFD. The integration covers the E1 SPF panels in 15 layups from 78-3s to 315-9l, 3 to 12-3/8 in. thick and up to 64 ft long, for load-bearing floors, roofs and walls. The panel values are taken from the integrated database.

Start Designing for Free → Back to Nordic Structures → ICC-ES ESR-4875 · Issue Date: September 2024

The engineer's guide

Designing Nordic Structures CLT to the NDS

Nordic Structures (Montreal, Quebec; manufactured in Chibougamau) produces Nordic X-Lam cross-laminated timber. In the US it is recognized under ICC-ES ESR-4875, rated to ANSI/APA PRG-320. SPEC Toolbox designs the panels to the NDS, in allowable stress design or LRFD.

Product range

The integration covers Nordic X-Lam, cross-laminated SPF panels face-bonded with a non-formaldehyde exterior structural adhesive.

  • The E1 grade, with 1950f-1.7E SPF in the major direction and No. 3 SPF in the minor direction, in 3 to 9 layers.
  • Fifteen layups from 78-3s to 315-9l, gross thickness 3 to 12-3/8 in., in panels up to about 8 ft 10 in. wide and 64 ft long.
  • Applications in floor, roof and wall panels.

Compatibility

At a glance, in the US scope the Nordic X-Lam panels support:

  • Load-bearing floors, roofs and walls.
  • Allowable stress design (ASD) or LRFD.
  • Dry service (in-service moisture content below 16 percent).
  • Compliance with the California, Los Angeles and Chicago building codes.

What's distinctive

  • A full layup range, with values in both directions. Fifteen layups from 78-3s to 315-9l (gross thickness 3 to 12-3/8 in.) each carry effective bending capacity, bending and shear stiffness and shear in the major and minor directions.
  • Designed in ASD or LRFD. The reference design values convert to LRFD strengths through the NDS Table 10.3.1 factors.
  • Non-formaldehyde adhesive. The panels are face-bonded with a non-formaldehyde exterior structural adhesive.
  • Broad US code coverage. The panels carry California, Los Angeles and Chicago building-code supplements in addition to the base IBC and IRC recognition.

In the platform

The Nordic X-Lam panels are available across the SPEC Toolbox CLT modules, worked in ASD or LRFD to the NDS:

  • CLT floor, CLT wall and CLT shear wall.

and in the connection modules:

  • the screw connection module and the panel-to-panel connection details (spline, butt joint and half-lap);
  • CLT floor-to-glulam beam, CLT floor-to-floor and CLT wall-to-wall connections.

Panel behaviour is taken from the integrated database with the reference design values of ESR-4875, using a minimum specific gravity of 0.42 for fastener design.

Design codes

Design follows the ANSI/AWC NDS under the IBC and IRC. ICC-ES ESR-4875 publishes ASD reference design values for Nordic X-Lam, rated to ANSI/APA PRG-320: effective bending capacity, bending and shear stiffness, and in-plane shear, in the major and minor directions. These are adjusted per NDS Table 10.3.1, without the lumber size factor, with a creep factor of 2.0 applied to long-term deflection; LRFD strengths are obtained by multiplying by the NDS Table 10.3.1 factors. The laminations are SPF with a minimum specific gravity of 0.42, the basis for connection design per the NDS. The evaluation is for dry service (in-service moisture content below 16 percent); fire resistance is determined by calculation per NDS Chapter 16 or by test to ASTM E119. The panels also carry California, Los Angeles and Chicago building-code supplements.

More from this partner

Other Nordic Structures Integrations

CLT (cross-laminated timber) design icon
CLT

CLT

CSA O86 (CSA O86:19) Calculator →
Glulam beam and column design icon
Glulam

Glulam

CSA O86 (CSA O86:19) Calculator →
Glulam beam and column design icon
Glulam

Glulam

the NDS (ANSI/AWC NDS) under the IBC / IRC Calculator →
Frequently asked questions

FAQs

How current is the Nordic Structures CLT data in SPEC Toolbox?

It is written against ICC-ES ESR-4875, reissued September 2024 (subject to renewal September 2026), including its California, Los Angeles and Chicago supplements. Values are re-checked against the report at its next reissue before the integrated data changes.

Which Nordic Structures CLT products are part of the integration?

Nordic X-Lam in the E1 SPF grade, 3 to 9 layers, in 15 layups from 78-3s to 315-9l (gross thickness 3 to 12-3/8 in.), in panels up to about 8 ft 10 in. wide and 64 ft long.

What can the panels be used for?

Load-bearing floors, roofs and walls, in ASD or LRFD, in dry service (in-service moisture content below 16 percent).

FOR ENGINEERSStart designing now

Free, browser-based, no download. Design any certified connection into your real materials in seconds.

Start Designing For Free →